Rv furnace igniter not clicking.
The problem is when the blower works and the heater doesn t ignite it is the board inside heater it will have to be pulled out and replaced it is inside your heater unit chances are if you were at a camp site and you didn t have a device to control spikes it zapped your igniter board.
The blower and propane solenoids are working fine and i m getting a 63 65 volt reading on the igniter wire using a digital voltmeter with the igniter wire connected at both ends.
A faulty or dirty ignition or sensor is a relatively easy fix so follow these steps and you may be able to solve the problem yourself.
But there will be times when the furnace will blow a freshly replaced fuse as well.
The furnace may make a click sound but it wont start.
This is typically the problem if you can hear your furnace click on but it does not fire up.
This is pretty standard and it only requires putting in a new fuse.
Forest river rv model.
Rv furnace igniter not working.
Sometimes an rv furnace will blow a fuse while working.
The dsi is an acronym direct spart ignition it s an electronic igniter that uses a spark ignites the gas air mix.
August 20th 2017.
Knowledge of multi meter use is essential.
If the furnace is in warranty then you will get it.
A good way to test this out is to run the blower blower is apt to operate fine under 10 5 v if the blower runs then that means the battery supply may be under 10 5 v and thus its not able to open the furnace valve.
Rv furnace blowing fuses.
When winter arrives most service calls i get are for furnace repair.
Rv furnace clicks but won t start.
The ducts carry the heated air from the furnace to the interior of the rv.
The exhaust is an air outlet on the exterior of the rv that exhausts the gases produced during the combustion process the gases are a combination of carbon dioxide and carbon.
Rv furnace operates with a 10 5 v supply and at times if the battery is not able provide above 10 5v then the furnace wont ignite.
Otherwise your furnace won t start.
This has to be fixed and its a good idea to take technical help here.
In other words there s an ignition system malfunction that needs to be fixed.
I have a 2001 teton with an atwood model 8531 iv dclp that won t ignite.
Most likely your furnace is making a clicking noise and not providing heat because your furnace s spark igniter is trying to ignite your pilot light or burners but is failing to do so.
The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite.
This happens when the spark igniter try s to ignite the pilot light but fails.
First of all not knowing what you are doing with a gas fired appliance can be dangerous no matter how easy it looks on youtube.
Atwood furnace won t ignite.